Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Journal of Environmental Engineering (Japan) ; 88(806):300-306, 2023.
Article in Japanese | Scopus | ID: covidwho-2316074

ABSTRACT

From the early stages of the COVID-19 outbreak, there have been many reports on cluster infections in clubs and bars. Meanwhile, there is no report on the indoor air environment in those places and it will limit measures for infection control. This study aims to understand the indoor air and ventilation environment and to propose practical and appropriate improvement measures for related industries. In addition to measuring CO2 concentration in clubs and bars in Tokyo, we have surveyed the voluntary measures taken against COVID-19, outlines of building and ventilation/air conditioning equipment, ventilation regime, and so on. © 2023 Architectural Institute of Japan. All rights reserved.

2.
Atmosphere ; 14(1), 2023.
Article in English | Scopus | ID: covidwho-2241383

ABSTRACT

The importance of effective ventilation as one of the measures against COVID-19 is widely recognized worldwide. In Japan, at the early stage of the pandemic, in March 2020, an official announcement was made about basic ventilation measures against COVID-19. WHO also used the term "long-range aerosol or long-range airborne transmission” for the first time in December 2021. Based on the aerosol infection control measures before 2021 by the Japanese government, we conducted experiments on methods related to partition placement as an element of effective ventilation methods. In July 2022, the governmental subcommittee on Novel Coronavirus Disease Control provided an emergent proposal about effective ventilation methods to prevent two types of aerosol infection;infection by large aerosol on the air current and infection by small floating aerosol diffusion in a room. They also showed the way of setting droplet prevention partitions, which do not block off ventilation based on this investigation's results. © 2023 by the authors.

3.
Atmosphere ; 14(1):150, 2023.
Article in English | MDPI | ID: covidwho-2199715

ABSTRACT

The importance of effective ventilation as one of the measures against COVID-19 is widely recognized worldwide. In Japan, at the early stage of the pandemic, in March 2020, an official announcement was made about basic ventilation measures against COVID-19. WHO also used the term 'long-range aerosol or long-range airborne transmission';for the first time in December 2021. Based on the aerosol infection control measures before 2021 by the Japanese government, we conducted experiments on methods related to partition placement as an element of effective ventilation methods. In July 2022, the governmental subcommittee on Novel Coronavirus Disease Control provided an emergent proposal about effective ventilation methods to prevent two types of aerosol infection;infection by large aerosol on the air current and infection by small floating aerosol diffusion in a room. They also showed the way of setting droplet prevention partitions, which do not block off ventilation based on this investigation's results.

4.
Japan Architectural Review ; 5(2):225-232, 2022.
Article in English | ProQuest Central | ID: covidwho-1777519

ABSTRACT

Advances in next‐generation sequencing (NGS) technologies since 2005 have revolutionized biological science. One particular application of NGS technologies is to elucidate microbiomes in built environments. We are currently conducting a series of studies on the elucidation and control of mass infection mechanisms based on dynamic measurement of environment microbiomes. The objective of this study is to clarify the dispersion characteristics of oral bacteria in the built environment. Bacterial communities from occupants’ hands and oral cavities, doorknobs, desk and keyboard surfaces, and air in laboratories were investigated in seven Japanese universities. The median relative abundances of Firmicutes, Proteobacteria, Actinobacteria, Bacteroidetes, and Fusobacteria were 41%, 31%, 12%, 7%, and 3%, respectively. Moreover, the main genera detected were Streptococcus (27.6%), Haemophilus (7.0%), Staphylococcus (5.6%), Neisseria (5.6%), Corynebacterium (4.7%), Rothia (3.2%), Prevotella (3.0%), Fusobacterium (2.6%), Veillonella (1.7%), Leptotrichia (1.7%), Enhydrobacter (1.7%), Lactobacillus (1.3%), Acinetobacter (1.3%), and Actinomyces (1.1%). The oral bacteria Actinomyces, Corynebacterium, Fusobacterium, Haemophilus, Leptotrichia, Neisseria, Prevotella, Rothia, and Streptococcus were observed in indoor air and on surfaces as well as in oral cavities. Furthermore, Prevotella melaninogenica and Rothia mucilaginosa were observed in all samples, including those from hands and oral cavities, doorknobs, desk and PC keyboard surfaces, and air in laboratories, in all seven universities.

5.
JAPAN ARCHITECTURAL REVIEW ; n/a(n/a), 2021.
Article in English | Wiley | ID: covidwho-1293128

ABSTRACT

Abstract It is still undetermined if the main infection route of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus that leads to coronavirus disease 2019 (COVID-19), is infection through droplet, contact, or airborne transmission. However, confined spaces with poor ventilation are cited as a risk factor for group outbreaks, and there is growing interest in the effects of intervention through the appropriate operation of air-conditioning and sanitary equipment to reduce the risk of airborne transmission. This study first offers an outline of the characteristics of the novel coronavirus disease and the cluster outbreak case reports that have been clarified until now. Subsequently, we describe the appropriate operating conditions for building equipment that are effective in reducing the risk of infection and also highlight specificities for each building use based on the guidance provided by healthcare institutions and with reference to the standard recommendations by Western academic societies related to building equipment.

6.
Environ Health Prev Med ; 25(1): 66, 2020 Nov 03.
Article in English | MEDLINE | ID: covidwho-901839

ABSTRACT

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a new zoonotic agent that emerged in December 2019, causes coronavirus disease 2019 (COVID-19). This infection can be spread by asymptomatic, presymptomatic, and symptomatic carriers. SARS-CoV-2 spreads primarily via respiratory droplets during close person-to-person contact in a closed space, especially a building. This article summarizes the environmental factors involved in SARS-CoV-2 transmission, including a strategy to prevent SARS-CoV-2 transmission in a building environment. SARS-CoV-2 can persist on surfaces of fomites for at least 3 days depending on the conditions. If SARS-CoV-2 is aerosolized intentionally, it is stable for at least several hours. SARS-CoV-2 is inactivated rapidly on surfaces with sunlight. Close-contact aerosol transmission through smaller aerosolized particles is likely to be combined with respiratory droplets and contact transmission in a confined, crowded, and poorly ventilated indoor environment, as suggested by some cluster cases. Although evidence of the effect of aerosol transmission is limited and uncertainty remains, adequate preventive measures to control indoor environmental quality are required, based on a precautionary approach, because COVID-19 has caused serious global damages to public health, community, and the social economy. The expert panel for COVID-19 in Japan has focused on the "3 Cs," namely, "closed spaces with poor ventilation," "crowded spaces with many people," and "close contact." In addition, the Ministry of Health, Labour and Welfare of Japan has been recommending adequate ventilation in all closed spaces in accordance with the existing standards of the Law for Maintenance of Sanitation in Buildings as one of the initial political actions to prevent the spread of COVID-19. However, specific standards for indoor environmental quality control have not been recommended and many scientific uncertainties remain regarding the infection dynamics and mode of SARS-CoV-2 transmission in closed indoor spaces. Further research and evaluation are required regarding the effect and role of indoor environmental quality control, especially ventilation.


Subject(s)
Betacoronavirus/physiology , Coronavirus Infections/prevention & control , Coronavirus Infections/transmission , Environment, Controlled , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Pneumonia, Viral/transmission , Aerosols , Air Pollution, Indoor/prevention & control , COVID-19 , Crowding , Humans , SARS-CoV-2 , Ventilation
7.
JAPAN ARCHITECTURAL REVIEW ; n/a(n/a), 2020.
Article | WHO COVID | ID: covidwho-724624

ABSTRACT

Information on air-conditioning and ventilation has been continuously disseminated in response to the Japanese Government's announcement of the need for appropriate ventilation measures against the new coronavirus disease (COVID-19), and the issuing of an emergency presidential discourse by the presidents of Engineering Societies. In this paper, we add to the information the latest knowledge on the behavior of SARS-CoV-2 in air, describe its diffusion characteristics in the built environment, and summarize the effects of temperature and humidity on the virus. Then we recommend varying approaches of air-conditioning control for facility type.

SELECTION OF CITATIONS